1. Performance
| Parameter | Specification | Notes |
|---|
| Resolution per revolution | 24 bit | — |
| System accuracy | ± 120 ″ (typical) | Tolerance depends on installation; see installation instructions¹ |
| Signal noise (σ) | 10 ″ | Repeatability standard deviation² |
| Measurable absolute revolutions | 4,096 | — |
| Available memory | 2,048 Byte | — |
¹ According to DIN ISO 1319-1, upper and lower error limits depend on installation. Values apply to symmetrical conditions.
² According to DIN 1319-1:1995 standard deviation for repeatability.
2. Interface
| Parameter | Specification | Notes |
|---|
| Coding direction | Increases when shaft rotates clockwise viewed from direction “A” (see dimension drawing) | — |
| Communication interface | BiSS C | — |
3. Electrical Parameters
| Parameter | Specification | Notes |
|---|
| Connection type | Plug, 6-pin¹ | 4-pin: communication interface (RS-485, BiSS C BP3), 2-pin: current |
| Supply voltage | ≥ 5 V² | ±10% for BiSS C |
| Current consumption | Max. 150 mA | — |
¹ 4-pin for communication, 2-pin for power.
² Supply voltage tolerance ±10%.
4. Mechanical Parameters
| Parameter | Specification | Notes |
|---|
| Shaft type | Blind hollow shaft | — |
| Shaft diameter | 6 mm | — |
| Weight | ≤ 0.1 kg | — |
| Operating speed | 6,000 min⁻¹ (continuous), 7,500 min⁻¹ (short-term) | — |
| Angular acceleration | -100,000 rad/s² | — |
| Permissible static shaft displacement | ± 0.5 mm (axial ± 0.1 mm, radial¹) | ¹ Accounts for thermal expansion and mechanical mounting |
5. Environmental Parameters
| Parameter | Specification | Notes |
|---|
| Operating temperature | –20 °C … +105 °C | — |
| Storage temperature | –20 °C … +105 °C (unpackaged) | — |
| Relative humidity / condensation | 90%, no condensation allowed | — |
| Shock resistance | 100 g, 6 ms | EN 60068-2-27 |
| Vibration resistance | 20 g, 5 Hz … 2,000 Hz | EN 60068-2-6 |
| Electromagnetic compatibility | EN 61000-6-2:2016, EN 61000-6-4:2006, IEC 61000-6-7:2014 | — |
| Enclosure protection | IP20 | IEC 60529-1 |